Anti-Dengue NS1 Monoclonal Antibody (Detector Coupling)
High-avidity matched pairing partner for PVBSP802, yielding clean background and sharp positive band within 15 minutes.
Technical Datasheet & Analytical Specifications
Biological Target Biology & Epitope Mechanism
Binds quaternary epitopes on the native hexameric secreted Dengue non-structural protein 1 (sNS1). Conformation-specific capture eliminates cross-reactivity with Zika, West Nile, and Yellow Fever NS1 proteins while maintaining balanced pan-serotype sensitivity across all four Dengue serotypes (DENV-1, DENV-2, DENV-3, DENV-4).
Industrial Wet-Lab SOP & Dispensing Formulation
1.0 - 1.5 mg/mL in 10 mM PBS (pH 7.4). Dispense rate: 1.0 µL/cm on high-flow nitrocellulose (CN95/CN140).
Adjust 40nm colloidal gold to pH 8.0 - 8.2 using 0.1M K2CO3. Conjugate at 9 - 11 µg protein/mL sol. Post-block with 1% BSA and 0.5% PEG-20000.
1.0% BSA + 0.05% Tween-20 + 2% Trehalose in 10 mM PBS (pH 7.4).
Desiccated vacuum drying at 37°C for 3 hours, packaged with molecular sieve desiccant (<15% RH).
Matched Reagent Pairing & Assay Architecture
Analytical Sensitivity & Performance Benchmarks
Lot-Specific Certificate of Analysis (CoA) Guarantee
Every order includes comprehensive analytical documentation including SDS-PAGE densitometry scans, ELISA binding curves, protein concentration (BCA/A280), and sterility testing reports. Manufactured under rigorous batch quality assurance protocols.
Technical & Sourcing FAQ for Anti-Dengue NS1 Monoclonal Antibody (Detector Coupling)
Does PVBSP803 cross-react with Zika Virus NS1?
No. Cross-reactivity screening demonstrates <0.02% cross-binding to recombinant Zika NS1 and Yellow Fever NS1 at physiological concentrations (up to 1,000 ng/mL).
What is the recommended matched pair for Dengue NS1 Rapid Antigen cassettes?
We recommend PVBSP802 (Capture Coat) on the nitrocellulose membrane paired with PVBSP803 (Detector Coupling) conjugated to 40nm colloidal gold nanoparticles.
Is PVBSP803 compatible with whole blood, serum, and plasma samples?
Yes. Reagents include surfactant-compatible epitopes ensuring clean migration and zero matrix interference from whole blood, heparin plasma, or EDTA serum.
What bulk batch volumes are available from Bangalore manufacturing?
Standard commercial supply ranges from 50mg to 500mg batch lots with locked lot reservation for high-volume diagnostic manufacturing contracts.
B2B Evaluation Samples & Bulk PO
Order 1mg – 5mg test vials for rapid assay optimization or request bulk commercial lot reservations with full Certificate of Analysis.
Related Diagnostic Reagents & Matched Antibodies
HIV 1 Coat Recombinant Antigen
High-affinity recombinant HIV-1 envelope antigen optimized for solid-phase coating in rapid lateral flow cassettes and ELISA microplates.
HIV 2 Coat Recombinant Antigen
Specifically engineered HIV-2 recombinant antigen for differential and combined diagnostic screening kits.
Technical Formulation Guides for Dengue Assays

Custom Rabbit Monoclonal vs. Mouse Hybridoma Antibody Production in India: Affinity, QC & Scale-Up Guide
When mouse hybridomas fail to yield picomolar affinity against small haptens, phospho-epitopes, or conserved cardiac markers like cTnI, custom rabbit monoclonal antibodies close the sensitivity gap. Here is our bench-level guide to custom monoclonal antibody development, 8-point QC acceptance criteria, and commercial scale-up in India.

India Custom Antibody Service Market & Custom Assay Development: How to Buy Monoclonal Antibodies Online (2026 Buyer Guide)
Why Indian IVD kit manufacturers are shifting away from 4-week US/EU imports toward domestic custom antibody production and turnkey custom assay development in Bangalore. Complete 2026 breakdown of India custom antibody market economics, landed cost savings, online 1mg–5mg sample ordering, and CDSCO/ISO 13485 CoA verification.

Solving High Background Noise and False Positives in Lateral Flow Immunoassays
Stop rewriting your blocking buffer recipe every time a test strip streaks pink. A frequent root-cause pattern across assay tech transfers traces back to dispensing humidity spikes, over-salted gold conjugates, or mismatched capillary flow rates.